<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MP-Bus Archives - Kepler Electronics</title>
	<atom:link href="https://kepler-elec.com/tag/mp-bus/feed/" rel="self" type="application/rss+xml" />
	<link>https://kepler-elec.com/tag/mp-bus/</link>
	<description>LOYTEC COMPETENCE CENTER</description>
	<lastBuildDate>Sun, 26 May 2024 11:09:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://kepler-elec.com/wp-content/uploads/1/2023/10/cropped-cropped-cropped-cropped-Kepler-Elec-Logo-2023-09-18-13-45-04-32x32.jpg</url>
	<title>MP-Bus Archives - Kepler Electronics</title>
	<link>https://kepler-elec.com/tag/mp-bus/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MP-Bus Interface</title>
		<link>https://kepler-elec.com/2024/03/29/mp-bus-interface/</link>
					<comments>https://kepler-elec.com/2024/03/29/mp-bus-interface/#respond</comments>
		
		<dc:creator><![CDATA[Maen Sirhan]]></dc:creator>
		<pubDate>Fri, 29 Mar 2024 08:31:39 +0000</pubDate>
				<category><![CDATA[Connectivity]]></category>
		<category><![CDATA[Gateway]]></category>
		<category><![CDATA[Interfaces]]></category>
		<category><![CDATA[LOYTEC]]></category>
		<category><![CDATA[MP-Bus]]></category>
		<guid isPermaLink="false">https://kepler-elec.com/?p=3907</guid>

					<description><![CDATA[<p>The LMPBUS-804 connects up to four MP-Bus channels with up to 64 MP-Bus slaves to the USB port of the L‑INX Automation Server, L‑ROC Controller or L‑GATE Gateway Controller.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/mp-bus-interface/">MP-Bus Interface</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><a href="https://www.loytec.com/products/interfaces/l-mpbus"></a></p>



<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="640" height="640" sizes="(max-width: 640px) 100vw, 640px" src="https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS.png" alt="MP-Bus Interface" class="wp-image-3908" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS.png 640w, https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS-300x300.png 300w" /></figure>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3907_049cd8-c9 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3907_5d8a86-57"><span class="kb-svg-icon-wrap kb-svg-icon-fas_file-pdf kt-svg-icon-list-single"><svg viewBox="0 0 384 512"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M181.9 256.1c-5-16-4.9-46.9-2-46.9 8.4 0 7.6 36.9 2 46.9zm-1.7 47.2c-7.7 20.2-17.3 43.3-28.4 62.7 18.3-7 39-17.2 62.9-21.9-12.7-9.6-24.9-23.4-34.5-40.8zM86.1 428.1c0 .8 13.2-5.4 34.9-40.2-6.7 6.3-29.1 24.5-34.9 40.2zM248 160h136v328c0 13.3-10.7 24-24 24H24c-13.3 0-24-10.7-24-24V24C0 10.7 10.7 0 24 0h200v136c0 13.2 10.8 24 24 24zm-8 171.8c-20-12.2-33.3-29-42.7-53.8 4.5-18.5 11.6-46.6 6.2-64.2-4.7-29.4-42.4-26.5-47.8-6.8-5 18.3-.4 44.1 8.1 77-11.6 27.6-28.7 64.6-40.8 85.8-.1 0-.1.1-.2.1-27.1 13.9-73.6 44.5-54.5 68 5.6 6.9 16 10 21.5 10 17.9 0 35.7-18 61.1-61.8 25.8-8.5 54.1-19.1 79-23.2 21.7 11.8 47.1 19.5 64 19.5 29.2 0 31.2-32 19.7-43.4-13.9-13.6-54.3-9.7-73.6-7.2zM377 105L279 7c-4.5-4.5-10.6-7-17-7h-6v128h128v-6.1c0-6.3-2.5-12.4-7-16.9zm-74.1 255.3c4.1-2.7-2.5-11.9-42.8-9 37.1 15.8 42.8 9 42.8 9z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/component/docman/doc_download/2226-lmpbus-804-datasheet">LMPBUS-804 Datasheet</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3907_2f88be-b6"><span class="kb-svg-icon-wrap kb-svg-icon-fas_file-pdf kt-svg-icon-list-single"><svg viewBox="0 0 384 512"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M181.9 256.1c-5-16-4.9-46.9-2-46.9 8.4 0 7.6 36.9 2 46.9zm-1.7 47.2c-7.7 20.2-17.3 43.3-28.4 62.7 18.3-7 39-17.2 62.9-21.9-12.7-9.6-24.9-23.4-34.5-40.8zM86.1 428.1c0 .8 13.2-5.4 34.9-40.2-6.7 6.3-29.1 24.5-34.9 40.2zM248 160h136v328c0 13.3-10.7 24-24 24H24c-13.3 0-24-10.7-24-24V24C0 10.7 10.7 0 24 0h200v136c0 13.2 10.8 24 24 24zm-8 171.8c-20-12.2-33.3-29-42.7-53.8 4.5-18.5 11.6-46.6 6.2-64.2-4.7-29.4-42.4-26.5-47.8-6.8-5 18.3-.4 44.1 8.1 77-11.6 27.6-28.7 64.6-40.8 85.8-.1 0-.1.1-.2.1-27.1 13.9-73.6 44.5-54.5 68 5.6 6.9 16 10 21.5 10 17.9 0 35.7-18 61.1-61.8 25.8-8.5 54.1-19.1 79-23.2 21.7 11.8 47.1 19.5 64 19.5 29.2 0 31.2-32 19.7-43.4-13.9-13.6-54.3-9.7-73.6-7.2zM377 105L279 7c-4.5-4.5-10.6-7-17-7h-6v128h128v-6.1c0-6.3-2.5-12.4-7-16.9zm-74.1 255.3c4.1-2.7-2.5-11.9-42.8-9 37.1 15.8 42.8 9 42.8 9z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/doc_download/2231-L-MPBUS-Installation-Instructions" target="_blank" rel="noreferrer noopener">L-MPBUS Installation Instructions</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3907_7fbc90-23"><span class="kb-svg-icon-wrap kb-svg-icon-fas_file-pdf kt-svg-icon-list-single"><svg viewBox="0 0 384 512"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M181.9 256.1c-5-16-4.9-46.9-2-46.9 8.4 0 7.6 36.9 2 46.9zm-1.7 47.2c-7.7 20.2-17.3 43.3-28.4 62.7 18.3-7 39-17.2 62.9-21.9-12.7-9.6-24.9-23.4-34.5-40.8zM86.1 428.1c0 .8 13.2-5.4 34.9-40.2-6.7 6.3-29.1 24.5-34.9 40.2zM248 160h136v328c0 13.3-10.7 24-24 24H24c-13.3 0-24-10.7-24-24V24C0 10.7 10.7 0 24 0h200v136c0 13.2 10.8 24 24 24zm-8 171.8c-20-12.2-33.3-29-42.7-53.8 4.5-18.5 11.6-46.6 6.2-64.2-4.7-29.4-42.4-26.5-47.8-6.8-5 18.3-.4 44.1 8.1 77-11.6 27.6-28.7 64.6-40.8 85.8-.1 0-.1.1-.2.1-27.1 13.9-73.6 44.5-54.5 68 5.6 6.9 16 10 21.5 10 17.9 0 35.7-18 61.1-61.8 25.8-8.5 54.1-19.1 79-23.2 21.7 11.8 47.1 19.5 64 19.5 29.2 0 31.2-32 19.7-43.4-13.9-13.6-54.3-9.7-73.6-7.2zM377 105L279 7c-4.5-4.5-10.6-7-17-7h-6v128h128v-6.1c0-6.3-2.5-12.4-7-16.9zm-74.1 255.3c4.1-2.7-2.5-11.9-42.8-9 37.1 15.8 42.8 9 42.8 9z"/></svg></span><span class="kt-svg-icon-list-text">Certificates: <a href="https://www.loytec.com/support/download/doc_download/2259-EC-Declaration-LMPBUS-804" target="_blank" rel="noreferrer noopener">EC</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3907_249d66-ae"><span class="kb-svg-icon-wrap kb-svg-icon-fe_download kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4"/><polyline points="7 10 12 15 17 10"/><line x1="12" y1="15" x2="12" y2="3"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/LMPBUS-804" target="_blank" rel="noreferrer noopener">Downloads</a></span></li>
</ul></div>



<p>The LMPBUS-804 connects up to four MP-Bus channels with up to 64 MP-Bus slaves to the USB port of the L‑INX Automation Server, L‑ROC Controller or L‑GATE Gateway Controller.</p>



<p>MP-Bus stands for Multi Point Bus. It is the Belimo Master/Slave bus system. The MP-Bus allows to connect up to 8 slaves to a master unit. By exclusively using latest design actuators (e.g. ..-MPL) it is possible to connect up to 16 slaves. The advantages of this bus include reduced wiring expenses and substantially higher functionality. Furthermore one sensor can be connected per MP-Bus slave. These sensors include active sensors, passive resistances sensors and switches. The sensor values can be read over the MP-Bus network.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="307" sizes="(max-width: 800px) 100vw, 800px" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/image-1.png" alt="" class="wp-image-4692" /></figure>



<p><a href="https://www.loytec.com/images/stories/lmbus/lmpbus/LMPBUS_LINX_USB_EN.png" target="_blank" rel="noreferrer noopener"></a></p>



<h3 class="wp-block-heading">MP-Bus Interface Products</h3>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide" />



<h4 class="wp-block-heading"><strong>LMPBUS-804</strong></h4>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img decoding="async" width="640" height="640" src="https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS.png" alt="MP-Bus Interface" class="wp-image-3908 size-full" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS.png 640w, https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/03/L-MPBUS-300x300.png 300w" sizes="(max-width: 640px) 100vw, 640px" /></figure><div class="wp-block-media-text__content">
<p>MP-Bus Interface for 16 devices per channel, up to 4 channels</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3907_b00b1a-3e kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3907_15614a-73"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/sales/quote-request/ldali-rm5-detail" target="_blank" rel="noreferrer noopener">Contact Sales for</a><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener"> quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3907_578d09-8f"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/lmpbus-804" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>
<p>The post <a href="https://kepler-elec.com/2024/03/29/mp-bus-interface/">MP-Bus Interface</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://kepler-elec.com/2024/03/29/mp-bus-interface/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
