<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>KSTAT-FC09-FVMN-24 Archives - Kepler Electronics</title>
	<atom:link href="https://kepler-elec.com/tag/kstat-fc09-fvmn-24/feed/" rel="self" type="application/rss+xml" />
	<link>https://kepler-elec.com/tag/kstat-fc09-fvmn-24/</link>
	<description>LOYTEC COMPETENCE CENTER</description>
	<lastBuildDate>Sat, 21 Sep 2024 17:40:56 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://kepler-elec.com/wp-content/uploads/1/2023/10/cropped-cropped-cropped-cropped-Kepler-Elec-Logo-2023-09-18-13-45-04-32x32.jpg</url>
	<title>KSTAT-FC09-FVMN-24 Archives - Kepler Electronics</title>
	<link>https://kepler-elec.com/tag/kstat-fc09-fvmn-24/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KSTAT-FC09-FVMN-24</title>
		<link>https://kepler-elec.com/2024/05/01/kstat-fc09-fvmn-24/</link>
		
		<dc:creator><![CDATA[Maen Sirhan]]></dc:creator>
		<pubDate>Wed, 01 May 2024 11:58:18 +0000</pubDate>
				<category><![CDATA[BMS Thermostat]]></category>
		<category><![CDATA[THERMOSTAT]]></category>
		<category><![CDATA[Thermostat]]></category>
		<category><![CDATA[Thermostat & AC Control]]></category>
		<category><![CDATA[BMS]]></category>
		<category><![CDATA[Kepler]]></category>
		<category><![CDATA[KSTAT-FC09-FVMN-24]]></category>
		<category><![CDATA[Modbus Fan Coil Thermostat]]></category>
		<guid isPermaLink="false">https://kepler-elec.com/?p=5607</guid>

					<description><![CDATA[<p>Modbus Fan Coil Thermostat KSTAT-FC09-FVMN-24</p>
<p>The post <a href="https://kepler-elec.com/2024/05/01/kstat-fc09-fvmn-24/">KSTAT-FC09-FVMN-24</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex">
<figure class="wp-block-image size-full"><a href="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_1.png" target="_blank" rel="noreferrer noopener"><img fetchpriority="high" decoding="async" width="381" height="381" sizes="(max-width: 381px) 100vw, 381px" data-id="5609" src="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_1.png" alt="Modbus Fan Coil Thermostat" class="wp-image-5609" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_1.png 381w, https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_1-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_1-300x300.png 300w" /></a></figure>



<figure class="wp-block-image size-full"><a href="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_2-.png" target="_blank" rel="noreferrer noopener"><img decoding="async" width="413" height="413" sizes="(max-width: 413px) 100vw, 413px" data-id="5610" src="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_2-.png" alt="" class="wp-image-5610" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_2-.png 413w, https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_2--150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_2--300x300.png 300w" /></a></figure>



<figure class="wp-block-image size-full"><a href="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_3.png" target="_blank" rel="noreferrer noopener"><img decoding="async" width="420" height="420" sizes="(max-width: 420px) 100vw, 420px" data-id="5611" src="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_3.png" alt="" class="wp-image-5611" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_3.png 420w, https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_3-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/05/KSTAT-FC09-FVMN-24_3-300x300.png 300w" /></a></figure>
</figure>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items5607_f82bbf-d9 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-5607_85a0b3-2f"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener">Contact Sales for quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-5607_ac7995-8c"><span class="kb-svg-icon-wrap kb-svg-icon-fe_download kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4"/><polyline points="7 10 12 15 17 10"/><line x1="12" y1="15" x2="12" y2="3"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://kepler-elec.com/wp-content/uploads/2024/05/KSTAT-FC09-FVMN-24-Modbus-Thermostat-V202403-R1.pdf" target="_blank" rel="noreferrer noopener">Download KSTAT-FC09-FVMN-24 Datasheet </a></span></li>
</ul></div>



<h3 class="wp-block-heading">Modbus Fan Coil Thermostat KSTAT-FC09-FVMN-24</h3>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<p>KSTAT-FC09 series fan coil thermostat is widely used in home, residential building, school, hotel, hospital, office and other environments.</p>



<p>It controls the 3-speed fan/0-10V EC fan and modulating valve in the central air-conditioning system by comparing the room temperature with set temperature to maintain the ideal room temperature.</p>



<p>It comes with a powerful built-in transformer that outputs 24VDC to the modulating valve (PICV) for energy and cost saving</p>
</div>



<h3 class="wp-block-heading has-medium-font-size">Features</h3>



<ul class="wp-block-list">
<li>Touch Panel, VA Screen</li>



<li>0-10V modulating valve control</li>



<li>Weekly Programmable Function</li>



<li>3 speed On/Off fan and EC fan integrated</li>



<li>2wire or 3 wire RS485 Modbus Communication</li>



<li>With 24VDC output power, output load for PICV &gt; 12VA</li>
</ul>



<h3 class="wp-block-heading has-medium-font-size">Specification</h3>



<figure class="wp-block-table"><table><tbody><tr><td><strong>Power Supply</strong></td><td>85-250Vac, 50/60Hz</td><td><strong>Inbuilt Sensor</strong></td><td>NTC3950, 10K</td></tr><tr><td><strong>Current Load</strong></td><td>0-10V Fan</td><td><strong>Temperature Accuracy</strong></td><td>±0.5°C</td></tr><tr><td>&nbsp;</td><td>Valve Relay 0-10V signal</td><td><strong>Set-Point Range</strong></td><td>5 ~ 50°C</td></tr><tr><td><strong>Storage Temp.</strong></td><td>-5 ~ 45 °C</td><td><strong>Display Temp. Range</strong></td><td>0 ~ 60°C</td></tr><tr><td><strong>Power Consumption</strong></td><td>&lt; 1.5W</td><td><strong>Working Environment</strong></td><td>0 ~ 50°C</td></tr><tr><td><strong>Housing Material</strong></td><td>PC +ABS (Fireproof)</td><td><strong>Installation Box</strong></td><td>Standard Electric Box</td></tr><tr><td><strong>Product Dimension</strong></td><td>86 x 86 x 39 mm</td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td><strong>Protection Class</strong></td><td>IP20</td><td><strong>Operating Buttons</strong></td><td>Capacitive Touch Buttons</td></tr></tbody></table></figure>



<h3 class="wp-block-heading has-medium-font-size">Dimensions and Display</h3>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="850" height="298" sizes="auto, (max-width: 850px) 100vw, 850px" src="https://kepler-elec.com/wp-content/uploads/1/2024/05/image-4.png" alt="" class="wp-image-5613"/></figure>



<h3 class="wp-block-heading has-medium-font-size">Typical Wiring</h3>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:61% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="563" height="455" src="https://kepler-elec.com/wp-content/uploads/1/2024/05/image-5.png" alt="" class="wp-image-5615 size-full"/></figure><div class="wp-block-media-text__content">
<p></p>



<h3 class="wp-block-heading has-medium-font-size">KSTAT-FC09-FVMN-24</h3>



<ul class="wp-block-list">
<li><em>AC85~250V</em></li>



<li><em>3 speed fan and EC fan</em></li>



<li><em>2 pipe system</em></li>



<li><em>Control 0~10V modulating valve</em></li>



<li><em>DC24V output-Modbus</em></li>
</ul>



<p></p>



<p></p>



<p></p>



<p> <em>Version2024-1.0</em></p>
</div></div>
<p>The post <a href="https://kepler-elec.com/2024/05/01/kstat-fc09-fvmn-24/">KSTAT-FC09-FVMN-24</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
