<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>BMS Software Archives - Kepler Electronics</title>
	<atom:link href="https://kepler-elec.com/tag/bms-software/feed/" rel="self" type="application/rss+xml" />
	<link>https://kepler-elec.com/tag/bms-software/</link>
	<description>LOYTEC COMPETENCE CENTER</description>
	<lastBuildDate>Sun, 26 May 2024 15:23:49 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://kepler-elec.com/wp-content/uploads/1/2023/10/cropped-cropped-cropped-cropped-Kepler-Elec-Logo-2023-09-18-13-45-04-32x32.jpg</url>
	<title>BMS Software Archives - Kepler Electronics</title>
	<link>https://kepler-elec.com/tag/bms-software/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>L-STUDIO 3 Engineering Tool</title>
		<link>https://kepler-elec.com/2024/04/02/l-studio-3-engineering-tool/</link>
					<comments>https://kepler-elec.com/2024/04/02/l-studio-3-engineering-tool/#respond</comments>
		
		<dc:creator><![CDATA[Maen Sirhan]]></dc:creator>
		<pubDate>Tue, 02 Apr 2024 16:28:06 +0000</pubDate>
				<category><![CDATA[BMS Software]]></category>
		<category><![CDATA[Buildings]]></category>
		<category><![CDATA[GRMS SOFTWARE]]></category>
		<category><![CDATA[Home Automation Software]]></category>
		<category><![CDATA[L-WEB]]></category>
		<category><![CDATA[Lighting Software]]></category>
		<category><![CDATA[LOYTEC]]></category>
		<category><![CDATA[BMS]]></category>
		<category><![CDATA[Engineering Tool]]></category>
		<category><![CDATA[GRMS Software]]></category>
		<category><![CDATA[L-STUDIO]]></category>
		<category><![CDATA[lighting Software]]></category>
		<category><![CDATA[software]]></category>
		<guid isPermaLink="false">https://kepler-elec.com/?p=4171</guid>

					<description><![CDATA[<p>L-STUDIO is the ultimate development and integration platform for programmable LOYTEC controllers, such as the L-INX automation servers, L-ROC room control system or programmable visualization solutions such as the LPAD-7. It combines the major building automation disciplines -programming, communication, and visualization - into a single tool</p>
<p>The post <a href="https://kepler-elec.com/2024/04/02/l-studio-3-engineering-tool/">L-STUDIO 3 Engineering Tool</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><a href="https://www.loytec.com/products/software/5996-l-studio-3"></a></p>



<div class="wp-block-media-text is-stacked-on-mobile"><figure class="wp-block-media-text__media"><img fetchpriority="high" decoding="async" width="300" height="300" src="https://kepler-elec.com/wp-content/uploads/1/2024/03/L-STUDIO-300x300.png" alt="L-STUDIO 3 Engineering Tool
" class="wp-image-4172 size-medium" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/03/L-STUDIO-300x300.png 300w, https://kepler-elec.com/wp-content/uploads/1/2024/03/L-STUDIO-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/03/L-STUDIO.png 647w" sizes="(max-width: 300px) 100vw, 300px" /></figure><div class="wp-block-media-text__content">
<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items4171_7b2e4d-f1 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-4171_57b0af-16"><span class="kb-svg-icon-wrap kb-svg-icon-fas_file-pdf kt-svg-icon-list-single"><svg viewBox="0 0 384 512"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M181.9 256.1c-5-16-4.9-46.9-2-46.9 8.4 0 7.6 36.9 2 46.9zm-1.7 47.2c-7.7 20.2-17.3 43.3-28.4 62.7 18.3-7 39-17.2 62.9-21.9-12.7-9.6-24.9-23.4-34.5-40.8zM86.1 428.1c0 .8 13.2-5.4 34.9-40.2-6.7 6.3-29.1 24.5-34.9 40.2zM248 160h136v328c0 13.3-10.7 24-24 24H24c-13.3 0-24-10.7-24-24V24C0 10.7 10.7 0 24 0h200v136c0 13.2 10.8 24 24 24zm-8 171.8c-20-12.2-33.3-29-42.7-53.8 4.5-18.5 11.6-46.6 6.2-64.2-4.7-29.4-42.4-26.5-47.8-6.8-5 18.3-.4 44.1 8.1 77-11.6 27.6-28.7 64.6-40.8 85.8-.1 0-.1.1-.2.1-27.1 13.9-73.6 44.5-54.5 68 5.6 6.9 16 10 21.5 10 17.9 0 35.7-18 61.1-61.8 25.8-8.5 54.1-19.1 79-23.2 21.7 11.8 47.1 19.5 64 19.5 29.2 0 31.2-32 19.7-43.4-13.9-13.6-54.3-9.7-73.6-7.2zM377 105L279 7c-4.5-4.5-10.6-7-17-7h-6v128h128v-6.1c0-6.3-2.5-12.4-7-16.9zm-74.1 255.3c4.1-2.7-2.5-11.9-42.8-9 37.1 15.8 42.8 9 42.8 9z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/component/docman/doc_download/2275-l%E2%80%91studio-3-datasheet" target="_blank" rel="noreferrer noopener">L-STUDIO Datasheet</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-4171_5f8a92-8b"><span class="kb-svg-icon-wrap kb-svg-icon-fe_download kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4"/><polyline points="7 10 12 15 17 10"/><line x1="12" y1="15" x2="12" y2="3"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/L-STUDIO" target="_blank" rel="noreferrer noopener">Downloads</a></span></li>
</ul></div>
</div></div>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<h3 class="wp-block-heading">L‑STUDIO 3</h3>



<p>L-STUDIO is the ultimate development and integration platform for programmable LOYTEC controllers, such as the L-INX automation servers, L-ROC room control system or programmable visualization solutions such as the LPAD-7. It combines the major building automation disciplines -programming, communication, and visualization &#8211; into a single tool. Together with the LWEB-900 building management system, it covers all phases of building automation, from prototyping to programming, configuration, and maintenance.</p>



<p>Achieving the highest levels of energy-efficiency and room comfort is only possible by forging all conventional controls into a single integrated building automation application. L-STUDIO helps to develop these applications in a timely and cost-effective manner. Template -based prototyping, reusable libraries and integrated testing tools support the project engineer’s efforts.</p>
</div>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<h3 class="wp-block-heading">Programming</h3>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<p>L-STUDIO speaks your language, ranging from the industry-proven PLC language IEC 61131 and its event-based successor IEC 61499 up to modern IoT applications using Node.js and Node-RED.</p>



<p>Using the cycle-based IEC 61131 language, classic applications such as boiler plants, air handling units or heating/cooling circuits can be easily automated. The LOYTEC building automation library already contains many sample applications that can be used as a starting point for your application.</p>



<p>Room control applications can be implemented using the LOYTEC L -ROC room automation library. It provides an integrated solution for HVAC, lighting, and sunblinds solution as well as many other functions required in the modern living space. The room automation library uses the IEC 61499 event -based language to create low -latency and fully networked applications that eliminate the need for classical network integration.</p>
</div>
</div>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<h3 class="wp-block-heading">Communication</h3>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<p>In L-STUDIO logic blocks, called CATs, can contain technology objects, such as BACnet objects or OPC tags as templates. Data points are then automatically created when a CAT is instantiated on a device. This makes the creating of network interfaces of different technologies almost automatic. A CAT can also contain technology level objects, such as alarms, schedules or trends which are also automatically instantiated and linked to the logic program. The L-STUDIO CATs support all LINX automation server technologies: BACnet, OPC XML/DA, Bluetooth, DALI, EnOcean, SMI, CEA -709, KNX, Modbus, M -Bus and will support future technologies yet to come.</p>



<p>State-of-the-art buildings require Internet of Things services, such as public trans ‑ port information, office booking systems or building information systems. These can be integrated using Node.js or Node-RED. Their integration allows classical PLC programming to be combined with latest web technologies.</p>
</div>
</div>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<h3 class="wp-block-heading">Visualization</h3>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<p>L-STUDIO CATs can also contain graphical symbols. These visualize the data points of the CAT and represent the logic object in a graphical way, such as a pump diagram, a room overview, or an entire plant display.</p>



<p>These symbols can be combined into graphical projects that can be used on L -VIS or L -PAD devices. The graphical projects can also be used on a PC with LWEB 802/803 or on mobile devices using the LWEB-APP. All visualizations are fully editable by the user and support all features of the L -VIS technology.</p>
</div>
</div>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<h3 class="wp-block-heading">Management</h3>



<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex">
<p>L-STUDIO projects can be imported into LWEB -900. All devices and graphical views are imported automatically. The parameter views of LWEB -900 allow to configure and optimize the devices that have been created by L-STUDIO. The graphical views can be used in LWEB-900 together with the access control functions to provide the building maintainers and end-users with a secure and consistent interface to the building.</p>



<p>L-STUDIO provides documentation and versioning features to keep track of the project. All library blocks can be documented in HTML-style. Libraries can also be versioned, distributed in binary form or managed in a source versioning tool to track and document changes.</p>
</div>
</div>



<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="1024" sizes="(max-width: 1024px) 100vw, 1024px" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/L-studio2-1024x1024.png" alt="" class="wp-image-4281" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/04/L-studio2-1024x1024.png 1024w, https://kepler-elec.com/wp-content/uploads/1/2024/04/L-studio2-1536x1536.png 1536w, https://kepler-elec.com/wp-content/uploads/1/2024/04/L-studio2-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/04/L-studio2-300x300.png 300w, https://kepler-elec.com/wp-content/uploads/1/2024/04/L-studio2-768x768.png 768w, https://kepler-elec.com/wp-content/uploads/1/2024/04/L-studio2.png 1653w" /></figure>



<h3 class="wp-block-heading">L-STUDIO 3 Engineering Tool Products</h3>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide" />



<h5 class="wp-block-heading">L-STUDIO</h5>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img decoding="async" width="90" height="53" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/L-STUDIO_90x105-3.png" alt="" class="wp-image-4296 size-full" /></figure><div class="wp-block-media-text__content">
<p>Device configuration and programming suite</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items4171_ac688d-15 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-4171_70ef6a-de"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener">Contact Sales for quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-4171_db813d-90"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/ltrain-lstudio" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>



<hr class="wp-block-separator has-alpha-channel-opacity" />



<h5 class="wp-block-heading">LTRAIN-LSTUDIO</h5>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="90" height="90" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/training_icon_90x105.png" alt="" class="wp-image-4286 size-full" /></figure><div class="wp-block-media-text__content">
<p>L-STUDIO Training (2 days)</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items4171_7b3934-00 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-4171_dd1625-59"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener">Contact Sales for quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-4171_395a42-72"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/ltrain-lstudio" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>
<p>The post <a href="https://kepler-elec.com/2024/04/02/l-studio-3-engineering-tool/">L-STUDIO 3 Engineering Tool</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://kepler-elec.com/2024/04/02/l-studio-3-engineering-tool/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LWEB-802 Visualization via Web Browser</title>
		<link>https://kepler-elec.com/2024/03/29/lweb-802-visualization-via-web-browser/</link>
					<comments>https://kepler-elec.com/2024/03/29/lweb-802-visualization-via-web-browser/#respond</comments>
		
		<dc:creator><![CDATA[Maen Sirhan]]></dc:creator>
		<pubDate>Fri, 29 Mar 2024 08:55:23 +0000</pubDate>
				<category><![CDATA[BMS Software]]></category>
		<category><![CDATA[Buildings]]></category>
		<category><![CDATA[GRMS SOFTWARE]]></category>
		<category><![CDATA[Home Automation Software]]></category>
		<category><![CDATA[L-WEB]]></category>
		<category><![CDATA[Lighting Software]]></category>
		<category><![CDATA[LOYTEC]]></category>
		<category><![CDATA[GRMS Software]]></category>
		<category><![CDATA[lighting Software]]></category>
		<category><![CDATA[LWEB]]></category>
		<category><![CDATA[software]]></category>
		<guid isPermaLink="false">https://kepler-elec.com/?p=3968</guid>

					<description><![CDATA[<p>LWEB‑802 is a platform in­de­pendent graphical user interface to visualize dynamic pages showing plant details or a virtual room operator panel in a standard web browser.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lweb-802-visualization-via-web-browser/">LWEB-802 Visualization via Web Browser</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><a href="https://www.loytec.com/products/lweb/lweb-802"></a></p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="500" height="500" sizes="auto, (max-width: 500px) 100vw, 500px" src="https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240-1.png" alt="LWEB-802 Visualization via Web Browser
" class="wp-image-3970" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240-1.png 500w, https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240-1-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240-1-300x300.png 300w" /></figure>



<p>LWEB‑802 is a platform in­de­pendent graphical user interface to visualize dynamic pages showing plant details or a virtual room operator panel in a standard web browser.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lweb-802-visualization-via-web-browser/">LWEB-802 Visualization via Web Browser</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://kepler-elec.com/2024/03/29/lweb-802-visualization-via-web-browser/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LWEB-803 Visualization</title>
		<link>https://kepler-elec.com/2024/03/29/lweb-803-visualization/</link>
					<comments>https://kepler-elec.com/2024/03/29/lweb-803-visualization/#respond</comments>
		
		<dc:creator><![CDATA[Maen Sirhan]]></dc:creator>
		<pubDate>Fri, 29 Mar 2024 08:54:46 +0000</pubDate>
				<category><![CDATA[BMS Software]]></category>
		<category><![CDATA[Buildings]]></category>
		<category><![CDATA[GRMS SOFTWARE]]></category>
		<category><![CDATA[Home Automation Software]]></category>
		<category><![CDATA[L-WEB]]></category>
		<category><![CDATA[Lighting Software]]></category>
		<category><![CDATA[LOYTEC]]></category>
		<category><![CDATA[BMS]]></category>
		<category><![CDATA[GRMS Software]]></category>
		<category><![CDATA[lighting Software]]></category>
		<category><![CDATA[LWEB]]></category>
		<category><![CDATA[software]]></category>
		<guid isPermaLink="false">https://kepler-elec.com/?p=3965</guid>

					<description><![CDATA[<p>LWEB‑803 is a graphical user interface to visualize dynamic pages showing plant details or a virtual room operator panel on a Microsoft Windows PC.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lweb-803-visualization/">LWEB-803 Visualization</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><a href="https://www.loytec.com/products/lweb/lweb-803"></a></p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="500" height="500" sizes="auto, (max-width: 500px) 100vw, 500px" src="https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240.png" alt="LWEB-803 Visualization
" class="wp-image-3966" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240.png 500w, https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-803_240-300x300.png 300w" /></figure>



<p>LWEB‑803 is a graphical user interface to visualize dynamic pages showing plant details or a virtual room operator panel on a Microsoft Windows PC.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lweb-803-visualization/">LWEB-803 Visualization</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://kepler-elec.com/2024/03/29/lweb-803-visualization/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LWEB-900 Integrated Building Management System</title>
		<link>https://kepler-elec.com/2024/03/29/lweb-900-integrated-building-management-system/</link>
					<comments>https://kepler-elec.com/2024/03/29/lweb-900-integrated-building-management-system/#respond</comments>
		
		<dc:creator><![CDATA[Maen Sirhan]]></dc:creator>
		<pubDate>Fri, 29 Mar 2024 08:52:46 +0000</pubDate>
				<category><![CDATA[BMS Software]]></category>
		<category><![CDATA[GRMS SOFTWARE]]></category>
		<category><![CDATA[L-WEB]]></category>
		<category><![CDATA[Lighting Software]]></category>
		<category><![CDATA[LOYTEC]]></category>
		<category><![CDATA[BMS]]></category>
		<category><![CDATA[GRMS Software]]></category>
		<category><![CDATA[lighting Software]]></category>
		<category><![CDATA[software]]></category>
		<guid isPermaLink="false">https://kepler-elec.com/?p=3961</guid>

					<description><![CDATA[<p>The integrated building management software LWEB‑900 provides a user interface to manage and operate a LOYTEC building management system. LWEB‑900 is a highly flexible and scalable solution which accompanies you from installation and configuration of LOYTEC devices (L‑INX Automation Servers, L‑IOB I/O Modules and Controllers with IP connectivity, L‑ROC Room Controllers, L‑GATE Gateways, L‑VIS Touch Panels, L‑DALI Controllers), all the way to daily operation of the facilities.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lweb-900-integrated-building-management-system/">LWEB-900 Integrated Building Management System</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><a href="https://www.loytec.com/products/lweb/lweb-900"></a></p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="500" height="500" sizes="auto, (max-width: 500px) 100vw, 500px" src="https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-900_240.png" alt="LWEB-900 Integrated Building Management System" class="wp-image-3962" srcset="https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-900_240.png 500w, https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-900_240-150x150.png 150w, https://kepler-elec.com/wp-content/uploads/1/2024/03/lweb-900_240-300x300.png 300w" /></figure>



<p>The integrated building management software LWEB‑900 provides a user interface to manage and operate a LOYTEC building management system. LWEB‑900 is a highly flexible and scalable solution which accompanies you from installation and configuration of LOYTEC devices (L‑INX Automation Servers, L‑IOB I/O Modules and Controllers with IP connectivity, L‑ROC Room Controllers, L‑GATE Gateways, L‑VIS Touch Panels, L‑DALI Controllers), all the way to daily operation of the facilities.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lweb-900-integrated-building-management-system/">LWEB-900 Integrated Building Management System</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://kepler-elec.com/2024/03/29/lweb-900-integrated-building-management-system/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LPA Protocol Analyzer</title>
		<link>https://kepler-elec.com/2024/03/29/lpa/</link>
					<comments>https://kepler-elec.com/2024/03/29/lpa/#respond</comments>
		
		<dc:creator><![CDATA[Maen Sirhan]]></dc:creator>
		<pubDate>Fri, 29 Mar 2024 08:26:43 +0000</pubDate>
				<category><![CDATA[BMS Software]]></category>
		<category><![CDATA[Buildings]]></category>
		<category><![CDATA[L-IP]]></category>
		<category><![CDATA[LOYTEC]]></category>
		<category><![CDATA[CEA‑709]]></category>
		<category><![CDATA[IP-852]]></category>
		<category><![CDATA[LonMark]]></category>
		<category><![CDATA[software]]></category>
		<guid isPermaLink="false">https://kepler-elec.com/?p=3903</guid>

					<description><![CDATA[<p>The LOYTEC Protocol Analyzer (LPA) for LonMark Systems captures all data packets on CEA‑709 or IP-852 networks and displays all recorded packets on a PC screen.</p>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lpa/">LPA Protocol Analyzer</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:61% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="200" height="202" src="https://kepler-elec.com/wp-content/uploads/1/2024/03/LPA.png" alt="LPA" class="wp-image-3904 size-full" /></figure><div class="wp-block-media-text__content">
<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3903_a629e7-1e kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_ddb2d3-2e"><span class="kb-svg-icon-wrap kb-svg-icon-fas_file-pdf kt-svg-icon-list-single"><svg viewBox="0 0 384 512"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M181.9 256.1c-5-16-4.9-46.9-2-46.9 8.4 0 7.6 36.9 2 46.9zm-1.7 47.2c-7.7 20.2-17.3 43.3-28.4 62.7 18.3-7 39-17.2 62.9-21.9-12.7-9.6-24.9-23.4-34.5-40.8zM86.1 428.1c0 .8 13.2-5.4 34.9-40.2-6.7 6.3-29.1 24.5-34.9 40.2zM248 160h136v328c0 13.3-10.7 24-24 24H24c-13.3 0-24-10.7-24-24V24C0 10.7 10.7 0 24 0h200v136c0 13.2 10.8 24 24 24zm-8 171.8c-20-12.2-33.3-29-42.7-53.8 4.5-18.5 11.6-46.6 6.2-64.2-4.7-29.4-42.4-26.5-47.8-6.8-5 18.3-.4 44.1 8.1 77-11.6 27.6-28.7 64.6-40.8 85.8-.1 0-.1.1-.2.1-27.1 13.9-73.6 44.5-54.5 68 5.6 6.9 16 10 21.5 10 17.9 0 35.7-18 61.1-61.8 25.8-8.5 54.1-19.1 79-23.2 21.7 11.8 47.1 19.5 64 19.5 29.2 0 31.2-32 19.7-43.4-13.9-13.6-54.3-9.7-73.6-7.2zM377 105L279 7c-4.5-4.5-10.6-7-17-7h-6v128h128v-6.1c0-6.3-2.5-12.4-7-16.9zm-74.1 255.3c4.1-2.7-2.5-11.9-42.8-9 37.1 15.8 42.8 9 42.8 9z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/component/docman/doc_download/110-lpa-datasheet">LPA Datasheet</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_467078-34"><span class="kb-svg-icon-wrap kb-svg-icon-fas_file-pdf kt-svg-icon-list-single"><svg viewBox="0 0 384 512"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M181.9 256.1c-5-16-4.9-46.9-2-46.9 8.4 0 7.6 36.9 2 46.9zm-1.7 47.2c-7.7 20.2-17.3 43.3-28.4 62.7 18.3-7 39-17.2 62.9-21.9-12.7-9.6-24.9-23.4-34.5-40.8zM86.1 428.1c0 .8 13.2-5.4 34.9-40.2-6.7 6.3-29.1 24.5-34.9 40.2zM248 160h136v328c0 13.3-10.7 24-24 24H24c-13.3 0-24-10.7-24-24V24C0 10.7 10.7 0 24 0h200v136c0 13.2 10.8 24 24 24zm-8 171.8c-20-12.2-33.3-29-42.7-53.8 4.5-18.5 11.6-46.6 6.2-64.2-4.7-29.4-42.4-26.5-47.8-6.8-5 18.3-.4 44.1 8.1 77-11.6 27.6-28.7 64.6-40.8 85.8-.1 0-.1.1-.2.1-27.1 13.9-73.6 44.5-54.5 68 5.6 6.9 16 10 21.5 10 17.9 0 35.7-18 61.1-61.8 25.8-8.5 54.1-19.1 79-23.2 21.7 11.8 47.1 19.5 64 19.5 29.2 0 31.2-32 19.7-43.4-13.9-13.6-54.3-9.7-73.6-7.2zM377 105L279 7c-4.5-4.5-10.6-7-17-7h-6v128h128v-6.1c0-6.3-2.5-12.4-7-16.9zm-74.1 255.3c4.1-2.7-2.5-11.9-42.8-9 37.1 15.8 42.8 9 42.8 9z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/doc_download/404-LPA/LPA-IP-User-Manual-3.7" target="_blank" rel="noreferrer noopener">LPA/LPA-IP User Manual</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_baf1a2-ef"><span class="kb-svg-icon-wrap kb-svg-icon-fe_download kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4"/><polyline points="7 10 12 15 17 10"/><line x1="12" y1="15" x2="12" y2="3"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/LPA-SW" target="_blank" rel="noreferrer noopener">Downloads</a></span></li>
</ul></div>
</div></div>



<p>The LOYTEC Protocol Analyzer (LPA) for LonMark Systems captures all data packets on CEA‑709 or IP-852 networks and displays all recorded packets on a PC screen. The LPA software provides a comprehensive set of functions and methods to view, filter, and analyze data packets down to bit level.</p>



<p>The long time recording capability helps to find even intermittent faults on the network. When the system is configured by an LNS based tool, the LPA software can browse the database in order to display the node and network variable names. Together with all LOYTEC devices featuring a Remote Network Interface (RNI), the LPA software can record packets even from remote twisted-pair channels.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="810" height="483" sizes="auto, (max-width: 810px) 100vw, 810px" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/image-3.png" alt="" class="wp-image-4698" /></figure>



<p>With a single mouse-click, the built-in report function creates reports (text files) showing the health condition of the investigated channel and gives hints and tips on how to solve problems on this channel.</p>



<p>The intuitive and easy-to-use LPA software runs on all LOYTEC network interfaces. On the NIC852 network interfaces, it supports the remote LPA functionality. Each LPA-SW license must be registered for one LOYTEC NIC.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="616" height="532" sizes="auto, (max-width: 616px) 100vw, 616px" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/image-4.png" alt="" class="wp-image-4699" /></figure>



<h3 class="wp-block-heading">Features</h3>



<ul class="wp-block-list">
<li>Online CEA‑709.1 packet monitoring in LonMark Systems</li>



<li>Packet interpretation down to bit-level</li>



<li>High resolution packet time-stamping</li>



<li>Advanced, context specific packet filter and converter manipulation</li>



<li>Conversion of network addresses and variables into symbolic names</li>



<li>dvanced Transaction Identification</li>



<li>Integrated Node Statistics for all detected domains, subnets, nodes, and groups</li>



<li>Extensive packet statistics (short packets, CRC errors, packets/‌s, etc.)</li>



<li>Statistic report function including hints and tips for solving network problems</li>



<li>Statistic report plug-in interface for localization or customization of the statistic report</li>



<li>Trend Logging for bandwidth utilization and packet errors</li>



<li>LNS® database interpretation</li>



<li>Interpretation of SNVTs, network management, and diagnostic messages</li>



<li>Displays SNVTs in ISO and Imperial US system</li>



<li>Long-term packet recording capability and error tracking in packets with protocol errors</li>



<li>Remote LPA function (needs LPA‑IP, LPA-SET-USB or LPA‑IP-SW plus NIC852) with L-IP, NIC709-IP, LVIS‑3E100, LVIS‑3ME7‑Gx, LVIS‑3ME12‑Ax, LVIS‑3ME15‑Ax, LVIS‑3ME15‑Gx, LINX‑10x, LINX‑11x, LINX‑12x, LINX‑15x, LROC‑10x, LGATE‑902, LGATE‑95x</li>
</ul>



<h3 class="wp-block-heading">LPA Products</h3>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide" />



<h4 class="wp-block-heading"><strong>LPA-SET-USB</strong></h4>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="150" height="150" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/LPA_SET_USB.png" alt="LPA_SET_USB" class="wp-image-4700 size-full" /></figure><div class="wp-block-media-text__content">
<p>Set contains: Network Interface NIC709-USB100 and NIC852, Protocol Analyzer Software LPA-IP-SW for IP-852 channels, supports remote LPA, registered to NIC852, and Protocol Analyzer Software LPA-SW for CEA‑709 channels, registered to NIC709-USB100</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3903_d4291d-9b kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_e147be-2d"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/sales/quote-request/ldali-rm5-detail" target="_blank" rel="noreferrer noopener">Contact Sales for</a><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener"> quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_4eb4d9-52"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/lpa-set-usb" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide" />



<h4 class="wp-block-heading"><strong>LPA-USB</strong></h4>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="150" height="150" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/LPA_SET_USB.png" alt="LPA-SET-USB" class="wp-image-4700 size-full" /></figure><div class="wp-block-media-text__content">
<p>Set contains: Network Interface NIC709-USB100, and Protocol Analyzer Software LPA-SW for CEA‑709 channels, registered to NIC709-USB100</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3903_933d07-87 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_7fed73-fb"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/sales/quote-request/ldali-rm5-detail" target="_blank" rel="noreferrer noopener">Contact Sales for</a><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener"> quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_4c5719-87"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/lpa-usb" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide" />



<h4 class="wp-block-heading"><strong>LPA-IP</strong></h4>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="90" height="90" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/LPA-IP.png" alt="" class="wp-image-4701 size-full" /></figure><div class="wp-block-media-text__content">
<p>IP-852 Channel Protocol Analyzer Bundle contains: Network Interface NIC852, Protocol Analyzer Software LPA-IP-SW for IP-852 channels, supports remote LPA, registered to NIC852</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3903_7d845c-52 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_a37eea-e6"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/sales/quote-request/ldali-rm5-detail" target="_blank" rel="noreferrer noopener">Contact Sales for</a><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener"> quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_6ea0b2-37"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/lpa-ip" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide" />



<h4 class="wp-block-heading">LPA-SW</h4>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="150" height="150" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/LPA_SW.png" alt="LPA_SW" class="wp-image-4702 size-full" /></figure><div class="wp-block-media-text__content">
<p>Protocol Analyzer Software, supports all NIC709 network interfaces, NIC709 not included</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3903_fb62bf-f9 kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_b7f97d-bd"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/sales/quote-request/ldali-rm5-detail" target="_blank" rel="noreferrer noopener">Contact Sales for</a><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener"> quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_fd31c0-9b"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/lpa-sw" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>



<hr class="wp-block-separator has-alpha-channel-opacity is-style-wide" />



<h4 class="wp-block-heading"><strong>LPA-IP-SW</strong></h4>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:15% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="150" height="150" src="https://kepler-elec.com/wp-content/uploads/1/2024/04/LPA_SW.png" alt="LPA_SW" class="wp-image-4702 size-full" /></figure><div class="wp-block-media-text__content">
<p>Protocol Analyzer Software for IP-852 channels, supports Remote LPA functionality, NIC852 not included</p>



<div class="wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items3903_f8521b-4d kt-svg-icon-list-columns-1 alignnone"><ul class="kt-svg-icon-list">
<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_dfe56f-25"><span class="kb-svg-icon-wrap kb-svg-icon-fe_mail kt-svg-icon-list-single"><svg viewBox="0 0 24 24"  fill="none" stroke="currentColor" stroke-width="2" stroke-linecap="round" stroke-linejoin="round" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z"/><polyline points="22,6 12,13 2,6"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/sales/quote-request/ldali-rm5-detail" target="_blank" rel="noreferrer noopener">Contact Sales for</a><a href="mailto:sales@kepler-elec.com" target="_blank" rel="noreferrer noopener"> quote request</a></span></li>



<li class="wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-3903_842421-cf"><span class="kb-svg-icon-wrap kb-svg-icon-ic_document kt-svg-icon-list-single"><svg viewBox="0 0 8 8"  fill="currentColor" xmlns="http://www.w3.org/2000/svg"  aria-hidden="true"><path d="M0 0v8h7v-4h-4v-4h-3zm4 0v3h3l-3-3zm-3 2h1v1h-1v-1zm0 2h1v1h-1v-1zm0 2h4v1h-4v-1z"/></svg></span><span class="kt-svg-icon-list-text"><a href="https://www.loytec.com/support/download/lpa-ip-sw" target="_blank" rel="noreferrer noopener">Documentation and Software</a></span></li>
</ul></div>
</div></div>
<p>The post <a href="https://kepler-elec.com/2024/03/29/lpa/">LPA Protocol Analyzer</a> appeared first on <a href="https://kepler-elec.com">Kepler Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://kepler-elec.com/2024/03/29/lpa/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
